Technology

Seismic isolation joint reaction force list

For 300mm seismic isolation

(Unit:kgf)

system name
F C・H V U
Nominal diameter rubber materials rubber materials metal materials rubber materials
High-pressure type
metal materials metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 90 15 40 70 115 4.71×P 100 90
25A 120 20 50 75 130 7.35×P 105 100
32A 160 20 80 85 140 12.06×P 125 180 115 170
40A 175 25 100 90 150 18.84×P 135 210 130 190
50A 210 25 140 105 180 29.44×P 160 250 155 230
65A 300 30 200 120 200 49.75×P 195 300 185 265
80A 305 35 240 235 390 75.36×P 330 510 315 470
100A 400 45 370 310 510 117.75×P 435 715 410 61
125A 470 50 450 435 730 183.98×P 610 950 560 855
150A 520 55 590 625 1040 264.94×P 815 1300 775 1190
200A 745 70 890 1050 471.00×P
250A 905 75 1100 735.94×P
300A 1000 95 1430 1059.75×P

For 400mm seismic isolation

(Unit:kgf)

System name
F C・H V U
Nominal diameter rubber materials rubber materials metal materials rubber materials
High-pressure type
metal materials metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 130 25 50 70 115 4.71×P 100 90
25A 175 30 70 75 130 7.35×P 105 100
32A 210 35 100 85 140 12.06×P 125 180 115 170
40A 235 40 130 90 150 18.84×P 135 210 130 190
50A 245 45 180 105 180 29.44×P 160 250 155 230
65A 310 55 270 120 200 49.75×P 195 300 185 265
80A 355 60 320 235 390 75.36×P 330 510 315 470
100A 440 80 490 320 530 117.75×P 450 740 420 630
125A 525 85 600 475 790 183.98×P 620 1060 600 915
150A 635 95 780 645 1080 264.94×P 840 1400 795 1230
200A 795 125 1180 1130 471.00×P
250A 965 135 1470 735.94×P
300A 1155 165 1910 1059.75×P

For 500mm seismic isolation

(Unit:kgf)

System name
F C・H V U
Nominal diameter Rubber materials Rubber materials Metal materials Rubber materials
High-pressure type
Metal materials Metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 160 40 60 70 115 4.71×P 100 90
25A 200 50 80 75 130 7.35×P 105 100
32A 220 60 120 85 140 12.06×P 125 180 115 170
40A 250 60 160 90 150 18.84×P 135 210 130 190
50A 300 70 220 105 180 29.44×P 160 250 155 230
65A 360 90 330 120 200 49.75×P 195 300 185 265
80A 410 100 400 235 390 75.36×P 330 510 315 470
100A 540 120 610 320 530 117.75×P 450 740 420 630
125A 610 130 740 475 790 183.98×P 620 1060 600 915
150A 750 150 970 645 1080 264.94×P 840 1400 815 1230
200A 950 190 1470 1130 471.00×P
250A 1180 210 1830 735.94×P
300A 1370 260 2380 1059.75×P
  • P is the maximum site working pressure (kfg/cm2)
  • The reaction force value may change without notice due to product specifications changes etc.

For 600mm seismic isolation

(Unit:kgf)

System name
F C・H V U
Nominal diameter Rubber materials Rubber materials Metal materials Rubber materials
High-pressure type
Metal materials Metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 190 60 60 70 115 4.71×P 100 90
25A 230 70 80 75 130 7.35×P 105 100
32A 270 80 120 85 140 12.06×P 125 180 115 170
40A 300 90 160 90 150 18.84×P 135 210 130 190
50A 320 100 220 105 180 29.44×P 160 250 155 240
65A 430 120 310 120 200 49.75×P 195 300 185 265
80A 440 130 390 240 400 75.36×P 330 520 320 480
100A 580 170 590 325 540 117.75×P 450 780 425 640
125A 700 190 730 475 790 183.98×P 620 1150 600 915
125A 700 190 730 475 790 183.98×P 620 1150 600 915
150A 830 200 960 670 1080 264.94×P 870 1510 820 1230
200A 1040 270 1440 1130 471.00×P
250A 1350 290 1820 735.94×P
300A 1590 360 2370 1059.75×P

For 700mm seismic isolation

(Unit:kgf)

System name
F C・H V U
Nominal diameter Rubber materials Rubber materials Metal materials Rubber materials
High-pressure type
Metal materials Metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 220 70 70 70 115 4.71×P 100 90
25A 260 90 90 75 130 7.35×P 105 100
32A 300 100 130 85 140 12.06×P 130 180 115 170
40A 340 110 180 90 150 18.84×P 135 210 130 190
50A 390 130 250 105 180 29.44×P 160 250 155 230
65A 490 160 360 120 200 49.75×P 195 300 185 265
80A 540 170 450 240 400 75.36×P 340 520 320 480
100A 710 230 680 330 550 117.75×P 465 770 430 650
125A 760 240 850 480 830 183.98×P 675 1205 605 955
150A 910 270 1110 685 1140 264.94×P 895 1600 835 1290
200A 1230 360 1680 1200 471.00×P
250A 1440 390 2120 735.94×P
300A 1770 480 2760 10059.75×P

For 800mm seismic isolation

(Unit:kgf)

System name
F C・H V U
Nominal diameter Rubber materials Rubber materials Metal materials Rubber materials
High-pressure type
Metal materials Metal materials
Horizontal installation Vertical installation 10K 20K 10K 20K 10K 20K
20A 200 65 70 70 115 4.71×P 100 90
25A 245 80 100 75 130 7.35×P 105 100
32A 285 90 130 85 140 12.06×P 130 180 115 70
40A 325 105 190 90 150 18.84×P 135 210 130 190
50A 370 120 260 105 180 29.44×P 160 250 155 230
65A 460 145 380 120 200 49.75×P 195 300 185 265
80A 515 165 460 250 410 75.36×P 350 535 330 490
100A 675 215 700 340 560 117.75×P 480 785 440 660
125A 725 230 890 495 830 183.98×P 695 1205 620 955
200A 1185 345 1850 1240 471.00×P
250A 1405 380 2230 735.94×P
300A 1730 470 2910 1059.75×P

For 300mm~600mm seismic isolation

(Unit:kgf)

System name H・V
Nominal diameter Metal materials(For refrigerant )
6.35/9.52/12.70/15.88/19.05/22.22/25.40 145
28.58/31.75/343.92/38.10 175

For 700mm・800mm seismic isolation

(Unit:kgf)

System name H・V
Nominal diameter Metal materials(For refrigerant )
6.35/9.52/12.70/15.88/19.05/22.22/25.40 180
28.58/31.75/343.92/38.10 215